Supplying various types of Teskam regulators in Iran, ready to cooperate with oil, gas and petrochemical industries
Pressure regulator operation
The regulator automatically controls the outlet pressure to remain constant at a certain set pressure. The pressure regulator is normally open and closes gradually as the outlet pressure increases
The correct direction of steam flow from inside the pressure regulator is indicated by an arrow on its body
The position of the plug and our free space between the plug and the seat controls the amount of steam flowing out
The controlled output pressure is transmitted to the diaphragm through the condensate source and the control line and is placed in the reverse force position
This force, like the force exerted by the springs, is used to adjust the position of the plug, but in the opposite direction
The amount of force applied by the springs can be changed by the adjusting nut
This pressure relief valve is equipped with a stainless steel accordion piece that balances the inlet pressure
The inlet pressure is applied to the outer surface of the accordion piece and thus the forces acting on the surface of the plug are neutralized by this reverse force