The concept of power analyzer
To devices designed to calculate energy, power, active and reactive power, power factor (PF) and current, voltage measurement, power meter or Power Analyzer (Powermeter) is called. Power represents energy per unit time and its unit is watts, and in electricity, power is calculated by multiplying current by voltage. In electrical systems, especially in alternating current, we need to analyze many factors that are important in how energy is transferred, produced and consumed in electrical equipment.Harmonic Analyzer Or power analyzers are built to measure parameters such as current, voltage, harmonic perturbation and many power quality parameters.
Power Analyzer It has a clamp for measuring current and voltage of three phases and also has software for analyzing probes. An essential tool for any electrical circuit is the power analyzer. Battery voltage can be controlled before and after the flight with the help of a power analyzer. The battery pack must be balanced and the voltage, current and power of the system must be controlled. All this works with the help of this Power Analyzers It can be done.
What is a harmonic?
The effect of the third harmonic on the main waveform. Harmonics are voltages and electric currents that occur in a power grid due to some type of electrical charge.
The cause of harmonics
in the alternating and normal currents of power networks is sinusoidal voltage at a certain frequency, usually 50 or 60 Hz, when a linear baroelectric is connected to the system, in which case a sinusoidal current is formed with the same voltage frequency.
Once a non-linear load, such as rectifiers, is connected to the power system, they create a current that is not exactly sinusoidal. The flow waveform can be completely complicated depending on the type of load and its interaction with other components of the system. Regardless of the complexities of the current waveform described by the Fourier series analysis, it is possible to break down a wave into a simple wave that occurs at the power system frequency, at an exact multiple of the original frequency. More examples of nonlinear loads include common office equipment, such as computers and printers, as well as adjustable speed drives.
Power measuring device (power analyzer)
It can measure voltage (volts), current (amps), power (watts) and power capacity (ampere-hours).
Measurable quantities of power meters (power analyzers): 1) AC / DC current 2) AC / DC voltage 3) Frequency 3) Power factor 4) Watts 5) Active power 6) Reactive power 7) Phase angle 8) Real power 9) Power Appearance
of Power Analyzers (Power Meters)
1) Graphic power analyzer with flexible clamp
2) Clamp watt meter
3) Power leak
analyzer 4) Single phase and 3 phase harmonic power analyzer 5) Power
meter
6) Watt meter
7) Single phase power analyzer
8) Three phase power analyzer
Application of Power Analyzers (Harmonic Analyzers):
In the industries
for location, troubleshooting, forecasting and preventing possible problems of distribution and transmission networks
for use in sound studios
for use in data processing companies – companies that have sensitive servers.
Industrial electricity operators
Estimating reactive, active, and grid
unique devices for network analysis
Large
factories Small workshops
Commercial consumers and shops
Hotels
Office buildings
Residential and commercial complexes
Hospitals and single-phase power transformer testing ……